-> shotw faulty
Target | Property | Value
-------------------+-----------------------+-----------------------------------
/SP/faultmgmt/0 | fru | /SYS/PM0
/SP/faultmgmt/0/ | class | fault.chassis.voltage.fail faults/0 | |
/SP/faultmgmt/0/ | sunw-msg-id | SPT-8000-DH faults/0 | |
/SP/faultmgmt/0/ | component | /SYS/PM0 faults/0 | |
/SP/faultmgmt/0/ | uuid | 89505ca9-38b7-40e9-d5c9-b8b73851a5 faults/0 | bf
/SP/faultmgmt/0/ | timestamp | 2015-01-03/19:31:09 faults/0 | |
/SP/faultmgmt/0/ | fru_part_number | 7051795 faults/0 | |
/SP/faultmgmt/0/ | fru_rev_level | 04 faults/0 | |
/SP/faultmgmt/0/ | fru_serial_number | 465769T+1321L90NH5 faults/0 | |
/SP/faultmgmt/0/ | fru_manufacturer | Celestica Holdings PTE LTD faults/0 | |
/SP/faultmgmt/0/ | fru_name | Proc-Mod,3.0G,T4-4 faults/0 | |
/SP/faultmgmt/0/ | system_manufacturer | Oracle Corporation faults/0 | |
/SP/faultmgmt/0/ | system_name | SPARC T4-4 faults/0 | |
/SP/faultmgmt/0/ | system_part_number | 31747710+1+1 faults/0 | |
/SP/faultmgmt/0/ | system_serial_number | AK00000000 faults/0 | |
/SP/faultmgmt/0/ | chassis_manufacturer | Oracle Corporation faults/0 | |
/SP/faultmgmt/0/ | chassis_name | SPARC T4-4 faults/0 | |
/SP/faultmgmt/0/ | chassis_part_number | 31747710+1+1 faults/0 | |
/SP/faultmgmt/0/ | chassis_serial_number | AK00000000 faults/0 | |
/SP/faultmgmt/0/ | system_component_manu | Oracle Corporation faults/0 | facturer | /SP/faultmgmt/0/ | system_component_name | SPARC T4-4 faults/0 | |
/SP/faultmgmt/0/ | system_component_part | 31747710+1+1 faults/0 | _number |
/SP/faultmgmt/0/ | system_component_seri | AK00000000 faults/0 | al_number |
/SP/faultmgmt/0/ | diagnosis_engine | fdd 1.0 faults/0 | |
-> satrt /sp/faultmgmt/shell
Are you sure you want to start /SP/faultmgmt/shell (y/n)? y
faultmgmtsp> fmadm faulty
------------------- ------------------------------------ -------------- --------
Time UUID msgid Severity
------------------- ------------------------------------ -------------- --------
2015-01-03/19:31:09 89505ca9-38b7-40e9-d5c9-b8b73851a5bf SPT-8000-DH Critical
Fault class : fault.chassis.voltage.fail
FRU : /SYS/PM0
(Part Number: 7051795)
(Serial Number: 465769T+1321L90NH5)
Description : A chassis voltage supply is operating outside of the
allowable range.
Response : The system will be powered off. The chassis-wide service
required LED will be illuminated.
Impact : The system is not usable until repaired. ILOM will not allow
the system to be powered on until repaired.
Action : Please refer to the associated reference document at
http://support.oracle.com/msg/SPT-8000-DH for the latest
service procedures and policies regarding this diagnosis.
faultmgmtsp> fmadm repair 89505ca9-38b7-40e9-d5c9-b8b73851a5bf
No faults found
faultmgmtsp> exit
-> exit